Chapter 5: Installation
Installing a PCDPM
Page 5-184
Inter-Tel
®
5000 Installation Manual – Issue 2.4, May 2008
Figure 5-70.
AC Transformer Requirements for PCDPMs
IMPORTANT
DSS/BLF Units, MDPMs, and SLAs always require separate AC transformers. Older PCDPMs, part
no. 550.3014 [PB2548-A], require AC transformers when they are connected to DSS/BLF Units.
PCDPMs do not require AC transformers when they are used for OHVA only or have attached
MDPMs.
AC
DSS/BLF
PC/OUTPUT
DEVICE
Data device or
single line endpoint
AC = AC transformer required
ENDPOINT
PCDPM
PCDPM
PCDPM
PCDPM
PCDPM
SLA
AC
Single line endpoint
&/or DID trunk
AC*
PCDPM
AC*
For Off-Hook Voice Announce only
AC
DSS/BLF
* The AC transformer for the PCDPM is only required if using part no. 550.3014 [PB2548-A].
AC
MDPM
AC
DSS/BLF
AC
MDPM
AC
DSS/BLF
AC
MDPM
Data device or
single line endpoint
Data device or
single line endpoint
ENDPOINT
ENDPOINT
ENDPOINT
ENDPOINT
ENDPOINT
(1250 mA)
(450 mA)
(450 mA)
(450 mA)
Summary of Contents for Inter-Tel 5000