Chapter 5: Installation
Installing DID Trunks on an SLA (USA Only)
Inter-Tel
®
5000 Installation Manual – Issue 2.4, May 2008
Page 5-133
Installing DID Trunks on an SLA (USA Only)
Connect the Direct Inward Dialing (DID) trunks to the Single-Line Adapters as outlined below.
See Figure 5-57 on
page 5-133
. DID trunks are also supported through T1 circuits. In addition
to DID trunks, SLAs can also be used to install single line endpoints, playback devices, and off-
premises extension (OPX) stations. Any combination using the two ports on the SLA is possible.
For a diagram, see Figure 5-58 on
page 5-134
.
1.
Mount one four-conductor modular jack assembly next to each telephone company RJ
jack.
2.
For each modular jack assembly mounted in step
1
, mount a corresponding four-
conductor modular jack assembly near the SLA location.
3.
To connect the modular jack assemblies mounted in steps 1 and 2:
a. Run one-pair cable between the corresponding modular jack assemblies.
b. Wire each end of the one-pair cables onto their respective modular jack assemblies.
For a wiring diagram, see Figure 5-57 on
page 5-133
.
4.
Plug one end of a two-pair, mod-to-mod line cord into each RJ jack and plug the other
end into the corresponding modular jack assembly beside it.
5.
At the MDF backboard, plug one end of a two-pair mod-to-mod line cord into each
modular jack assembly. After programming the DEM-16 port, insert the plug into the
Circuit 1 or Circuit 2 jack on the SLA, as applicable. See “Programming an SLA for Dual
DID Trunks” on
page 5-134
.
Figure 5-57.
SLA Terminations for DID Trunks (USA Only)
Modular
Jack Assemblies
Endpoint Modular
Jack Assembly
SLA
AC Transformer
Standard Reversing
Mod-to-Mod Line Cord
To Telco
RJ
To Telco
RJ
TIP
RING
TIP
G
Y
BK
R
BK
R
RING
G
Y
G
R
R
G
Y
BK
BK
Y
G
Y
BK
R
RING
TIP
If a single line endpoint is located near the SLA, it can be plugged directly into the unit.
To
DEM
Block
Summary of Contents for Inter-Tel 5000
Page 1: ...Inter Tel 5000 M I T E L Installation and Maintenance Manual ...
Page 2: ......
Page 3: ...Issue 2 4 May 2008 Inter Tel 5000 Installation and Maintenance Manual Part Number 580 8000 ...
Page 4: ......
Page 6: ......
Page 20: ......
Page 62: ......
Page 366: ......
Page 432: ......
Page 467: ......
Page 468: ...Part No 580 8000 Issue 2 4 May 2008 A691 9111A ...