Appendices
MS-860 Industrial Raster Reader User’s Manual
A-9
Reader Setup
Tracking
<
K520,
tracking>
Scan Speed
<
K500,
scan speed>
Automatic Gain Control
<
K504,
gain level,AGC sampling,AGC min,AGC max>
Symbol Detect Status
<
K505,
symbol detect status,transition counter>
Maximum Element
<
K502,
maximum element>
Raster/Laser
Raster Setup
<
K506,
raster status,top offset,bottom offset,raster sweep rate,read
cycle on/off>
Laser Setup
<
K700,
laser on/off status,laser framing status,laser on position,laser off
position,laser power>
Symbologies
Code 39
<
K470,
status,check digit status,check digit output status,large interchar-
acter gap,fixed symbol length status,default symbol length,full ASCII
set>
Code 128/EAN-128
<
K474,
status,fixed symbol length status,fixed symbol length,EAN-128
status
,output format,application record separator status,application
record separator character,application record brackets,application record
padding>
Interleaved 2 of 5
<
K472,
status,check digit status,check digit output status,symbol length
#1,symbol length #2,guard bar status,range mode>
Codabar
<
K471,
status,start & stop match status,start & stop output status,large
intercharacter gap,fixed symbol length status,symbol length,check digit
type,check digit output status>
UPC/EAN
<
K473,
UPC status,EAN status,supplementals status,separator sta-
tus,separator character,supplementals type,UPC-E output as UPC-A>
Code 93
<
K475,
status,fixed symbol length status,fixed symbol length>
RSS Expanded
<
K484,
status,fixed symbol length status,fixed symbol length>
RSS Limited
<
K483,
status>
RSS-14
<
K482,
status>
Pharmacode
<
K477,
status,fixed bar length status,fixed bar length,min. no. of
bars,bar widths,direction,fixed threshold value>
PDF417
<
K476,
status,[unused],fixed symbol length status,fixed symbol
length,decode at end of read>
Micro PDF417
<
K485,
status,[unused],fixed symbol length status,fixed symbol length>
Composite
<
K453,
mode,separator status,separator>
Narrow Margins/Symbology
ID
<
K450,
narrow margins status
,
symbology identifier>
Background Color
<
K451,
background color>
I-O Parameters
Symbol Data Output
<
K705,
symbol data output mode,when to output>
Noread Message
<
K714,
status,noread message>
Bad Symbol Message
<
K715,
bad symbol status,bad symbol message>
No Symbol Message
<
K716,
no symbol status,no symbol message>
Output Indicators
<
K750,
green flash mode,[unused],green flash duration>
Beeper
<
K702,
beeper output>
Serial Verification
<
K701,
serial command echo status,serial command beep status,con-
trol/hex output>
Complete List of Serial Configuration Commands
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com