Using ESP
MS-860 Industrial Raster Reader User’s Manual
2-13
Send/Receive Options
To access
Receive
,
Save
and
Default
options, click the
Send/Recv
button: You can also access this selector by right-clicking in any of the
configuration views.
Receiving
From the
Send/Recv selector, select
Receive Reader Settings.
Caution
: Do not select this option if you do not want to upload the reader’s settings.
For example, if your
ESP file has a number of custom settings that you want to main-
tain and download into the reader, these settings would be lost by choosing
Yes.
This is useful if you want to receive (upload) the reader’s settings and save them as a
computer file for later retrieval. For example, if your reader has settings that you do not
want to change, choosing
Yes would allow you to load those settings to ESP and save
as an
ESP file for later retrieval.
Receiving the reader’s settings will also assure that you will not be subsequently saving
any unwanted changes that you or someone else previously made in
ESP.
Saving
1.
Send, No Save
.
(same as
<A>
)
This saves
ESP
settings to current
memory.
2.
Send and Save
.
(same as
<Z>
)
This activates all changes in current memory
and saves to the reader for
power-on.
3.
Send and Save as Customer Defaults.
(same as
<Zc>
)
(This option will be visible only if you had checked
Enable ‘Send and Save as
Customer Defaults’ in ESP Preferences in the Options menu.)
Use this to save your own set of default settings that you can quickly retrieve with
a
<Zrc>
command.
For more on defaulting and saving settings, see
"Defaulting/Saving/Resetting"
on
page A-16.