Sequence On Mismatch
11-10
MS-860 Industrial Raster Reader User’s Manual
Sequence On Mismatch
Note: Matchcode must be set to Sequential for this command to function.
The reader will sequence the master to one more/less than the decoded symbol. As an
example of
Sequence On Mismatch
Enabled
, consider the following decodes:
As an example of
Sequence On Mismatch
Disabled
, consider the following decodes:
Usage:
Enable this parameter if every trigger event should have a decode
and
more than one consecutive mismatch may occur.
Disable this parameter if every trigger event should have a decode but no
more than one consecutive mismatch may occur.
Definition:
When set to
Enabled, the master symbol sequences on every decode,
match or mismatch.
When set to
Disabled, the master symbol will not sequence whenever
consecutive mismatches occur.
Serial Cmd:
<
K223,
matchcode type,sequential matching,match start position,
match length,wild card character,sequence on noread,
sequence on
mismatch
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Master
symbol
Decoded
symbol
Master symbol after decode
001
001
002
002
002
003
003
abc
004 (sequenced on mismatch)
004
004
005
005
def
006 (sequenced on mismatch)
006
ghi
007 (sequenced on mismatch)
007
007
008
Master
symbol
Decoded
symbol
Master symbol after decode
001
001
002
002
002
003
003
abc
004 (sequenced because of previous match)
004
004
005
005
def
006 (sequenced because of previous match)
006
ghi
006 (not sequenced because of previous mismatch)
006
006
007
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com