Matchcode
MS-860 Industrial Raster Reader User’s Manual
11-13
Mismatch Replace
Status
Note: In addition to enabling Mismatch Replace, you will need to have done the following:
1. Enable a triggered read cycle in
"Trigger"
on page 7-6.
2. Enable
"Matchcode Type"
on page 11-4.
3. Enable
"Symbol Data Output"
on page 10-4.
Mismatch Replacement Message
Usage:
Useful when a user-defined message is needed in place of the mismatch
code message.
Definition:
When enabled, the
Mismatch Replace message is output instead of the
bar code data when a mismatch occurs.
Serial Cmd:
<
K736,status,
message>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Creates the ASCII string that will replace the configured master symbol
data that is read whenever a mismatch occurs.
Serial Cmd:
<
K736,
status,
message
>
Default:
MATCH
Options:
1 to 128 valid ASCII characters