I/O Parameters
MS-860 Industrial Raster Reader User’s Manual
10-7
Noread Message
Noread Status
Noread Message
Note: Noread Message will only be transmitted if Symbol Output (
"Symbol Data
Output Status"
on page 10-4) is set to
Match, Mismatch or Good Read.
Noread Message can be set to any ASCII characters except
NULL
,
<
,
>
, and
,
.
Usage:
Used in applications where the host needs serial verification that a sym-
bol has not been read and especially useful in new print verification.
Definition:
When enabled, and if no symbol has been decoded before timeout or the
end of the read cycle, the noread message will be transmitted to the
host.
Serial Cmd:
<
K714,status
,noread message>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Definition:
Any combination of ASCII characters can be defined as the noread
message.
Serial Cmd:
<
K714,
status,
noread message
>
Default:
NOREAD
Options:
1 to 128 ASCII characters.