Embedded Menus
A-24
MS-860 Industrial Raster Reader User’s Manual
Appendix J — Embedded Menus
In addition to
ESP, you can also use a communications menu such as Microsoft’s Hyper-
Terminal
™
to establish communication with Microscan’s embedded menus.
1
Because of
size/space limitations of embedded menus, their structures and terms may not pre-
cisely match those of
ESP or this manual.
1. With your host connected to MS-860, set your host communications settings as
follows:
9600
baud,
7
Data Bits,
1
Stop Bits, and
None
Parity.
2. Set
Flow Control to
None
.
3. Make the communications port selection. (Usually
COM 1
for Windows.)
Upon connection, send a
<D>
command to bring up the main menu.
Menu navigation commands are case sensitive. Use the space bar or
N
to advance to
the next item,
CR
(return key) to select a highlighted item,
B
to return to the previous
item,
M
to return to the previous menu, and
ESC
to return to the Main menu or to exit
the program. When exiting the program, you will be prompted to save your active set-
tings for power up (
Y
or
N
). Typing Y will be equivalent to saving with a
<Z>
command.
1. If you are using Microsoft’s HyperTerminal program, you may find that the initial screen is not
visible when you call up the program with the
<D>
command. If this occurs, exit the embedded
menu with a
ESC
,
E
, and
N
sequence and repeat the
<D>
command.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com