Laser Setup
8-8
MS-860 Industrial Raster Reader User’s Manual
Laser On Position
Laser Off Position
Laser Power
Low power ~ 0.6 mW
Medium power ~ 1.0 mW
High power ~ 1.5 mW
Definition:
The Laser On Percentage of the full scan arc that the scan beam moves
through before the laser turns ON. For example, if set for 30, the laser
will be off during the first 30 percent of the scan.
Serial Cmd:
<
K700,
laser on/off status,laser framing status,
laser on position
,laser
off position,laser power>
Default:
10
Options:
10 to 90
Definition:
Percentage of the full scan arc that the scan beam moves through before
the laser turns OFF.
Notes:
The combined values of Laser
On Position and Laser Off Position can-
not exceed 100 percent, the total arc of one scan.
Laser
Off Position must always exceed the value of Laser On Position
for an actual laser scan to take place.
Serial Cmd:
<
K700,
laser on/off status,laser framing status,laser on position,
laser
off position
,laser power>
Default:
95
Options:
15 to 95
Usage:
Used to optimize read performance at different distances. Typically,
higher power is used at greater distances.
Definition:
Allows the user or calibration routine to select laser power setting.
Serial Cmd:
<
K700,
laser on/off status,laser framing status,laser on position,laser off
position,
laser power
>
Default:
High
Power (for low or medium density reader)
Options:
0 = Low
1 = Medium
2 = High