![Microscan MS-860 User Manual Download Page 232](http://html1.mh-extra.com/html/microscan/ms-860/ms-860_user-manual_1788323232.webp)
Utilities
MS-860 Industrial Raster Reader User’s Manual
15-11
Request Master Symbol Data
Request All Master Symbols Data
Delete Master Symbol Data
Store Next Symbol as Master Symbol
Definition:
Returns master symbol data for any enabled master symbols from 1 to
10.
For example, to request master symbol #5, enter
<K231?,5>
. The reader
transmits the following format:
<K231,5,data>
. If no master symbol
data available, the output will be:
<M5/?>
.
Serial Cmd:
Send <
K231?,master symbol number
,
master symbol data> to request
the current master symbol for a specific master symbol.
Returns all master symbols if no number is added before the question
mark.
Options:
1 to 10
Definition:
Returns master symbol data for all enabled master symbols from 1 to 10.
Serial Cmd:
Send
<K231?>
to request all current master symbols.
Definition:
Delete Master Symbol Data allows you to delete an enabled master
symbol.
Serial Cmd:
Send <
K231,master symbol number,
> to delete the master symbol.
Options:
1 to 10
Definition:
After you’ve set the size in the database, you can order the reader to
scan-in the next symbol as master symbol 1.
Serial Cmd:
<
Gmaster symbol number
>
To store the next symbol scanned as master symbol #1 send:
<G>
or
<G1>
. For all symbols numbers except 1, the number must be included.
Options:
1 to 10
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com