I/O Parameters
MS-860 Industrial Raster Reader User’s Manual
10-15
Input
Disabled
Reset Counts
Unlatch Output
Active State
When set to
Active Closed, the input function is activated when the input state is
energized. When set to
Active Open, the input function is activated when the input
state is de-energized.
Usage:
For example, an application is setup so that a mismatch stops the pro-
duction line by using outputs in a latch mode (see
"Output Mode (Out-
put 1)"
on page 10-18). A push button switch can be connected to the
input pin so that when pressed, it unlatches the output, allowing the line
to resume operations.
Definition:
A programmable, discrete input used to reset counters, outputs or control
optoelectrical settings.
Serial Cmd:
<
K730,input mode
,active state>
Default:
Disabled
Options:
0 = Disabled
1 = Reset Counts
2 = Unlatch Output
Definition:
When set to
Disabled there is no effect on operation.
Usage:
Primarily used in test mode. Can also be used to reset counters daily.
Definition:
When set to
Reset Counts, a transition to the active state of the input
will cause the reader to reset the internal counters (See
"Read Rate"
on
page 15-3).
Definition:
This setting is used in combination with any of the three discrete outputs
that are in
Unlatch Mode 1 (see
"Latch Mode 1 (Unlatch on Input
#1)"
on page 10-18). A transition to the active state will clear any of the
three outputs that were previously latched.
Definition:
Determines the state at which inputs will react to input signals.
Serial Cmd:
<
K730,
input mode,
active state
>
Default:
Active Closed
Options:
0 = Active Open
1 = Active Closed