Ordered Output
13-12
MS-860 Industrial Raster Reader User’s Manual
Ordered Output by Serial Command
Filter Index
Symbology Type
Symbol Length
Definition:
The filter sequence number from 1 to 12
Serial Cmd:
<
K744,filter index
,symbology type,length,wildcard character,place-
holder character,data,decode direction,check database number>
Default:
0
(0 = disabled)
Options:
Range 0 to 12
Definition:
User-assigned symbology type that the reader will search for.
If a match is found, the reader then checks
Length.
Serial Cmd:
<
K744,
filter index,
symbology type
,length,wildcard character,place-
holder character,data,decode direction,check database number>
Default:
0
Options:
0 = Any type
1 = I-2/5
2 = code 39
3 = code 128
4 = Codabar
5 = UPC
6 = PDF417
7 = EAN 128
8 = Code 93
9 = Pharmacode
10 = RSS
11 = MicroPDF
12 = Composite
Definition:
User-assigned symbol length that the reader will search for.
If the length is found, the reader then checks
Wild Card.
Serial Cmd:
<
K744,
filter index,symbology type,
length
,wildcard character,place-
holder character,data,decode direction,check database number>
Default:
0
(0 = any length)
Options:
0 to 128