Symbologies
MS-860 Industrial Raster Reader User’s Manual
9-31
Background Color
Autodiscriminate
Although
Autodiscriminate is not a configuration command, but it is included here as
a convenient tool for enabling most symbol types.
Note: If using an I 2/5 symbol, verify that the number of characters in the symbol
being scanned matches the symbol length enabled for the I 2/5 symbol type (default is
10 and 6).
Usage:
If the background is darker than the symbol, then enable black back-
ground.
Typically the background is white; but on PCBs for example, they can be
black.
Definition:
Allows the user to choose which symbol background (spaces and sur-
rounding medium) the reader can read.
Serial Cmd:
<
K451,background color
>
Default:
White
Options:
0 = White
1 = Black
Usage:
Commonly used for quick setup mode to detect symbol type. This is par-
ticularly useful for users who might be unfamiliar with their application’s
symbology.
Note: It does not alter individual fields such as Start/Stop, Fixed
Length, etc. These need to be setup individually.
Definition:
Enables all available symbology types except PDF417, UCC/EAN 128,
PDF417, Micro PDF417, and RSS. The user may also individually disable/
enable each symbology type.
Serial Cmd:
<P>
Default:
Code 39
(only)
Options:
<P>
Enables all codes except noted above.
<Q>
Enables Code 39 only
<R>
Enables Codabar only
<S>
Enables I 2/5 only
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com