I/O Parameters
MS-860 Industrial Raster Reader User’s Manual
10-23
Output 2
Output 2 has the same parameters and default settings as Output 1.
Trend Analysis (output 2)
Trend Analysis to Output 2 has the same parameters and default settings as Trend
Analysis to Output 1.
Diagnostic Warnings (output 2)
Diagnostic Warnings to Output 2 has the same parameters and default settings as
Diagnostic Warnings to Output 1.
Serial Cmd:
<
K811,
output on,output state,pulse width,output mode>
Definition:
Applies trend analysis settings to
Output 2.
Serial Cmd:
<
K781,
trend analysis mode,number of triggers,number to output
on,decodes/trigger threshold>
Definition:
Applies diagnostic warnings to
Output 2.
Serial Cmd:
<
K791,
over temperature,service threshold,unused,laser current
high,laser current low,low temp>