Raster Setup
8-4
MS-860 Industrial Raster Reader User’s Manual
Top Offset
Bottom Offset
Note
:
For single scan line operation, set
Top Offset equal to Bottom Offset or click on
the
Static Line option.
Note
:
Assigning a larger value to
Top Offset than Bottom Offset will park the raster
mirror in its “home” (default) position.
Definition:
Decreasing the
Top Offset value
causes the top of the raster pattern
to move up.
Serial Cmd:
<
K506,
raster status,
top offset
,bottom offset,raster sweep rate,read cycle
on/off>
Default:
88
Options:
0 to 255
Definition:
Increasing the
Bottom Offset
value causes the bottom of the
raster pattern to move down.
Serial Cmd:
<
K506,
raster status,top offset,
bottom offset
,raster sweep rate,read
cycle on/off>
Default:
167
Options:
0 to 255