Trigger
7-6
MS-860 Industrial Raster Reader User’s Manual
Trigger
Trigger Mode
Continuous Read
Definition:
The type of trigger event that will initiate the read cycle.
Serial Cmd:
<
K200,trigger mode,
trigger filter duration>
Default:
Continuous Read
Options:
0 = Continuous Read
1 = Continuous Read 1 Output
2 = External Level
3 = External Edge
4 = Serial Data
5 = Serial Data & External Edge
Usage:
Continuous Read is useful in testing symbol readability or reader func-
tions. It is not recommended for normal operations.
Definition:
In
Continuous Read, trigger input options are disabled, the reader is
always in the read cycle, and it will attempt to decode and output every
scan crossing a symbol.
When To Output and Noread options have no
effect on
Continuous Read.
Serial Cmd:
<
K200,0
>