![Microscan MS-860 User Manual Download Page 70](http://html1.mh-extra.com/html/microscan/ms-860/ms-860_user-manual_1788323070.webp)
Communications
MS-860 Industrial Raster Reader User’s Manual
6-9
Stop Bits, Aux Port
Data Bits, Aux Port
Aux Port Mode
Usage:
Only changed if necessary to match host setting.
Definition:
Allows the user to select the last one or two bits in each character to indi-
cate the end of the character.
Serial Cmd:
<
K101,
aux port mode,baud rate,parity,
stop bits
,data bits,daisy chain
ID status,daisy chain ID>
Default:
One
Options:
0 = One
1 = Two
Usage:
Only changed if necessary to match host setting.
Definition:
Number of bits in each character.
Serial Cmd:
<
K101,
aux port mode,baud rate,parity,stop bits,
data bits
,daisy chain
ID status,daisy chain ID>
Default:
Seven
Options:
0 = Seven
1 = Eight
Definition:
Determines the flow of data between the auxiliary port device(s), the
reader, and the host.
Serial Cmd:
<
K101,aux port mode
,baud rate,parity,stop bits,data bits,daisy chain
ID status,daisy chain ID>
Default:
Disabled
Options:
0 = Disabled
1 = Transparent
2 = Half duplex
3 = Full duplex
4 = Daisy chain
5 = Command Processing