Calibration
MS-860 Industrial Raster Reader User’s Manual
4-9
Symbology Detect
When enabled, all symbologies readable by the MS-860 except PDF417 and Pharma-
code will be attempted during calibration. Any new symbologies successfully decoded
during calibration will remain enabled at the end of the process. All enabled symbolo-
gies will remain enabled. For example, assume that only Code 39 is enabled at the
beginning of calibration and
Symbology Detect is enabled. If a Code 128 symbol is
read during calibration, then Code 128 as well as Code 39 will thereafter be enabled.
Definition:
When enabled, autodiscrimination is in effect during the calibration pro-
cess.
When disabled, only the current symbologies enabled will be considered
during the calibration process.
Serial Cmd:
<
K521,
raster options,video status,scan speed status,laser power sta-
tus,laser framing status,
symbology detect
>
Default:
Enabled
Options:
0 = Disable
1 = Enabled