End of Read Cycle
7-14
MS-860 Industrial Raster Reader User’s Manual
End of Read Cycle
Note: When to Output must be set to End of Read Cycle before this command can
be active.
End of Read Cycle Mode
Note: When operating in Continuous Read or Continuous Read 1 Output, the
reader is always in the read cycle.
Timeout
Definition:
The read cycle is the time during which the reader will attempt to read
and decode a symbol. At the end of a read cycle the reader stops reading
symbols and sends the symbol data or noread message to the host.
Definition:
A read cycle can be terminated by a new trigger, a timeout, or a combina-
tion of both.
Serial Cmd:
<
K220,end of read cycle
,read cycle timeout>
Default:
Timeout
Options:
0 = Timeout
1 = New Trigger
2 = Timeout & New Trigger
Usage:
Typically used with
Serial or Edge and Continuous One.
It is effective in highly controlled applications when the maximum length
of time between objects can be predicted. It assures that a read cycle
ends before the next bar coded object appears, giving the system extra
time to decode and transmit the data to the host.
Definition:
Timeout ends the read cycle when the time set in Read Cycle Timeout
elapses or “times out.”
If in
Continuous Read 1 Output, a timeout initiates a new read cycle
and allows the same symbol to be read again.
With either
External Edge, Serial Data, or Serial Data & Edge
enabled, a timeout ends the read cycle and symbol data or a noread mes-
sage is sent to the host.
With
External Level enabled, the read cycle does not end until the fall-
ing edge trigger or a timeout occurs. The next read cycle does not begin
until the next rising edge trigger.