Stacked Symbologies
9-28
MS-860 Industrial Raster Reader User’s Manual
Composite
When set to
Enabled or Required, will attempt to decode the composite component of
a linear symbol. The linear symbol can be RSS14, RSS Expanded, RSS Limited, UCC/
EAN-128, UPC-A, EAN-13, EAN-8, and UPC-E.
Note: When Composite is set to Enabled or Required, all UPC symbols are consid-
ered part of a Composite symbol.
Enabled
If set to
Enabled and it only decodes the linear component, it will output only the linear
component.
Required
If set to
Required, it must decode both the linear and the composite components; oth-
erwise it outputs a noread.
Separator Status
Separator Character
Note: If Separator Character has been changed to any other character and you wish
to re-define the separator as a comma, you will need to use
ESP or the embedded
menu.
Usage:
Allows reading by both linear and 2D readers.
Definition:
Combines 2D and linear width modulated symbology on the same symbol
where different messages can be read by each reader type.
Serial Cmd:
<
K453,mode
,separator status,separator>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
2 = Required
Usage:
Allows user to distinguish between the main and
Supplemental sym-
bols.
Definition:
This separator separates the linear symbol and the composite component.
Serial Cmd:
<
K453,
mode,
separator status
,separator>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
As required by the application.
Definition:
Allows the user to change the separator character from a comma to a
new character.
Serial Cmd:
<
K453,
mode,separator status,
separator
>
Default:
,
(
comma
)
Options:
Any ASCII character
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com