![Microscan MS-860 User Manual Download Page 179](http://html1.mh-extra.com/html/microscan/ms-860/ms-860_user-manual_1788323179.webp)
Matchcode Type
11-4
MS-860 Industrial Raster Reader User’s Manual
Matchcode Type
Note: When Matchcode is set to Enabled, Wild Card or Sequential, Number of
Symbols will default back to
1
(if set to any number greater than 1).
Definition:
Allows the user to choose the way that master symbols will be compared
with subsequently scanned symbols.
Note: First set Triggering Mode to
External
or
Serial
.
Serial Cmd:
<
K223,matchcode type
,sequential matching,match start position,
match length,wild card character,sequence on noread,sequence on mis-
match>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
2 = Sequential
3 = Wild Card
Disabled:
Has no effect on operations.
Enabled:
Instructs the reader to compare symbols or portions of symbols with the
master symbol.
Sequential
Matching:
Instructs the reader to sequence after each match (numeric only) and
compare symbols or portions of symbols for sequential numbers.
Note: If Matchcode Type is set to Sequential, Number of Symbols
will default back to
1 (if set to any number greater than 1).
Wild Card:
Allows the user to enter user defined wild card characters in the master
symbol.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com