I/O Parameters
MS-860 Industrial Raster Reader User’s Manual
10-25
Quality Output
Quality Output Separator
Note: For all serial configuration commands, the following characters cannot be
used:
,
<
,
>
, and
NULL.
Decodes/Trigger Status
Decode Direction Output
Usage:
Host system can monitor scanning performance (printing process, scan-
ning environment changes, etc.) by setting thresholds in their processing
or displaying the outputs for visual verification.
Definition:
Allows the host to track the number of good reads per trigger by append-
ing a five digit numeric field to the end of symbol data.
When enabled, symbol data is followed by a separator, followed by the
five digits in the form of 00000. For example, a certain symbol that has
been averaging 00100 decodes per read cycle suddenly drops to 00012,
this would be a good indication that a problem has arisen even though
good reads are still occurring.
Serial Cmd:
<
K704,quality output separator
,decodes/trigger status,decode direc-
tion status>
Default:
,
(comma)
Options:
Any ASCII character
Serial Cmd:
<
K704,
quality output separator,
decodes/trigger status
,decode direc-
tion status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
If enabled the decode direction is appended to the barcode output with a
quality output separator as an “F” (forward) or an “R” (reverse).
Serial Cmd:
<
K704,
quality output separator,decodes/trigger status,
decode direc-
tion status
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com