Calibration Options
4-8
MS-860 Industrial Raster Reader User’s Manual
Laser Power Status
Laser Framing Status
Note: See
"Laser Setup"
on page 8-6 for the current laser settings.
Disabled
If Laser Framing Status is disabled, the laser scan line is not changed and will continue
to operate per the
Laser Setup
<K700>
settings (
"Laser Setup"
on page 7-22).
Enabled
If
Laser Framing Status is enabled and the beginning and end of the symbol are
located during calibration, the
<K700>
Laser Setup parameters are changed as fol-
lows:
1. The
On Position and Off Position parameters for the beginning and end of the
symbol are updated.
2.
Laser Framing is set to
Enabled
.
If a symbol is not located, the
<K700>
Laser Setup parameters will not be changed.
Definition:
When checked,
Laser Power is not changed by calibration.
Laser power is minimized during the calibration
process.
When not checked, laser power becomes part
of the calibration process.
Serial Cmd:
<
K521,
raster options,video status,scan speed status,
laser power sta-
tus
,laser framing status,symbology detect>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Definition:
When enabled, laser framing is performed during calibration.
Serial Cmd:
<
K521,
raster options,video status,scan speed status,laser power sta-
tus,
laser framing status
,symbology detect>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com