I/O Parameters
MS-860 Industrial Raster Reader User’s Manual
10-11
Match (Green Flash)
Green flash LEDs will flash for less than 1 second when a match condition is met. If mul-
tisymbol is enabled, then green flash LEDs will illuminate only if all symbols qualify as a
match. If matchcode is disabled, then this mode will activate the LED's on a good read.
Mismatch (Green Flash)
Same as
On Match except it illuminates on a mismatch.
Green Flash Duration
Beeper Output Condition
Usage:
A visual verification that a good read has occurred.
Definition:
When a good read occurs, the Green flash LED's will illuminate and stay
on for the time set for the
Green Flash Duration value.
Serial Cmd:
<
K750,
green flash mode,[unused],
green flash duration
>
Default:
100
(1 second)
Options:
0 to 65535 (in 10mS increments)
Usage:
Provides an audible verification that either a good read, noread or EZ
Button action has occurred.
Definition:
A beep is emitted either after each good read of a symbol or after each
noread, according to the
Beeper Output Condition selection.
Note: Beeper will also sound if any of the following occur:
• the reader is defaulted a send/save command from
ESP or an Exit
command from any embedded menu.
• a
<Z>
,
<Zp>
,
<Zd>
, or
<K,1>
command is sent
Serial Cmd:
<
K702,beeper output
>
Default:
On Good Read
Options:
0 = Disabled
1 = On Good Read
2 = On Noread