1D Symbologies
9-10
MS-860 Industrial Raster Reader User’s Manual
Application Record Padding
Note: Output Format must be set to Application Record before this parameter can
take effect.
Definition:
Padding is the insertion of zeros to make up the maximum length of a
variable application record data field, except for the last field which does
not require padding.
When enabled, padding is included. When disabled, padding is omitted.
Note: Padding is never added to fixed length fields or to the last data
field of a symbol. Enabling or disabling
Record Padding will have no
effect on these.
Serial Cmd:
<
K474,
status,fixed symbol length status,fixed symbol length,EAN-128
status,output format,application record separator status,application
record separator character,application record brackets,
application
record padding
>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled