Symbologies
MS-860 Industrial Raster Reader User’s Manual
9-25
Minimum Bars
Bar Width Status
Direction
Fixed Threshold Value
Definition:
Specifies the direction that a bar can be read.
Serial Cmd:
<
K477,
status,fixed bar length status,fixed bar length,
min. no. of
bars
,bar widths,direction,fixed threshold value>
Default:
4
Options:
4 to 16
Serial Cmd:
<
K477,
status,fixed bar length status,fixed bar length,min. no. of bars,
bar widths
,direction,fixed threshold value>
Default:
Mixed
Options:
0 = Mixed
1 = Narrow
2 = Wide
3 = Fixed Threshold Value
Definition:
Specifies the direction that a bar can be read.
Serial Cmd:
<
K477,
status,fixed bar length status,fixed bar length,min. no. of bars,
bar widths,
direction
,fixed threshold value>
Default:
Forward
Options:
0 = Forward
1 = Reverse
Definition:
Used when
Bar Width Status field is set to Fixed Threshold Value.
Serial Cmd:
<
K477,
status,fixed bar length status,fixed bar length,min. no. of bars,
bar widths,direction,
fixed threshold value
>
Default:
400
Options:
1 to 65535
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com