I/O Parameters
MS-860 Industrial Raster Reader User’s Manual
10-17
Trend Analysis
Tracks the occurrences and frequency of mismatches, noreads, and the number of
decodes per trigger and output the results to output 1.
Disabled
No output.
Diagnostic Warning
Activates output 1 when a diagnostic warning condition is met. When enabled the
Out-
put State and Pulse Width settings (
<K810>
pulse, latch...) have no affect on out-
put. The output will remain active as long as one of the diagnostic warning conditions
persists. The output will go inactive whenever the warning condition no longer exists.
The output remains active as long as one of the diagnostic conditions is met.
In Read Cycle
Output is active during the read cycle.
Output State (Output 1)
Pulse Width (Output 1)
Definition:
Sets the output state of the discrete output.
Serial Cmd:
<
K810,
output on,
output state
,pulse width,output mode>
Default:
Normally Open
Options:
0 = Normally Open
1 = Normally Closed
Definition:
Sets the time in 10mS increments that the discrete output remains active.
Serial Cmd:
<
K810,
output on,output state,
pulse width
,
output mode>
Default:
50 mS
(0.05 seconds)
Options:
1 to 65535 (0.01 to 65.535 seconds)