Output Format
MS-860 Industrial Raster Reader User’s Manual
13-15
Number of Filters
For example:
<K745,1>
enables
Output Filters #1 setting.
<K745,3>
enables
Output Filters #1 to filter #3’s setting.
<K745,0>
disables all output filters. The reader will not perform any filtered output.
Examples to enable and setup filters 1 and 2:
Filter #1
Symbology type = Code 39, Length = disabled, Wildcard = ‘*’, placeholder = ‘?’,
data = “AB*” = 41422A
<K744,1,3,0,2A,3F,41422a>
Filter #2
Symbology type = Code 128, Length = 8, Wildcard = ‘*’, placeholder = ‘?’,
data = “NBC??FGH” = 4e42433f3f464748.
<K744,2,4,8,2A,3F,4e42433f3f464748>
<K745,2>
enables
Ordered Output. It also enables filter index1 and filter index2.
Let’s say we have four symbols, “NBCXYFGH”, “NBDXYFGH”, “123XYZ”, “ABCDE”. The
reader will registered two good reads only and transmit the following:“ABCDE”, “NBCX-
YFGH”.
Definition:
The number of filters that symbols will be compared against, up to the
specified number. For example, entering 7 means that filters #1 through
#7 will be enabled.
Serial Cmd:
<
K745,number of filters involved
>
Default:
0
Options:
0 to 12
Any number from 1 to 12 enables
Output Filtering. A zero (0) disables
Output Filtering. The reader will not perform any filtered output.