I/O Parameters
MS-860 Industrial Raster Reader User’s Manual
10-3
I/O Parameters by Serial Command
I-O Parameters
Symbol Data Output
<
K705,
symbol data output mode,when to output>
Noread Message
<
K714,
status,noread message>
Bad Symbol Message
<
K715,
bad symbol status,bad symbol message>
No Symbol Message
<
K716,
no symbol status,no symbol message>
Output Indicators
<
K750,
green flash mode,[unused],green flash duration>
Beeper
<
K702,
beeper output>
Serial Verification
<
K701,
serial command echo status,serial command beep status,con-
trol/hex output>
Input 1
<
K730,
input
mode,active state>
Output 1
<
K810,
output on,active state,pulse width,output mode>
Trend Analysis (1)
<
K780,
trend analysis mode,trigger evaluation period,number to output
on,decodes/trigger threshold>
Diagnostics (1)
<
K790,
over temperature,service threshold,[unused],laser current
high,laser current low,low temp>
Output 2
<
K811,
output on,output state,pulse width,output mode>
Trend Analysis (2)
<
K781,
trend analysis mode,number of triggers,number to output
on,decodes/trigger threshold>
Diagnostics (2)
<
K791,
over temperature,service threshold,unused,laser current
high,laser current low,low temp>
Output 3
<
K812,
output on,output state,pulse width,output mode>
Trend Analysis (3)
<
K782,
trend analysis mode,number of triggers,number to output
on,decodes/trigger threshold>
Diagnostics (3)
<
K792,
over temperature,service threshold,unused,laser current
high,laser current low,low temp>
Quality Output
<
K704,
quality output separator,decodes/trigger status,decode direction
status>
Database Number Output
<
K759,
status,separator>
Symbol Position Output
<
K758,
raster status,scan status,separator>
Read Duration Output
<
K706,
status,separator>
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com