146
XtrapulsPac – User Guide
Chapter 3 - Reference
Gearing global parameters:
Beside parameters defined in a sequence, the gearing function has other global parameters which are not defined
in the sequence and are applied to all gearing sequences.
Master input:
Defines:
- master input source
- master start position
- hardware inputs for starting.
Gearing ratio sets:
2 sets of selectable gearing ratios (numerator and denominator) can be used
Gearing control:
Allows controlling a gearing sequence by an external source (i.e. via fieldbus or
hardware input):
- ratio set select
- Slave Phase Shift start
Slave Phase Shift
Distance:
Defines the Slave Phase Shift value for slave position adjustment.
Supported keyword and parameters for a gearing sequence in sequence file:
Keyword
Direct parameter entry
Description
SeqType
0x3611-1
value = GEAR for SEQUENCE.TXT file or
value = 5 for direct parameter object
NextSeq 0x3611-2
see
sequence
parameters
SeqCount 0x3611-3
see
sequence
parameters
SeqLink 0x3611-4
see
sequence
parameters
Trigger 0x3611-5
see
sequence
parameters
Output 0x3611-6
0x3611-7
0x3611-8
see sequence parameters
StartCond 0x3611-9
0x3611-10
see sequence parameters
Tempo 0x3611-23
see
sequence
parameters
Config 0x3611-21
defines
the gearing behaviour
Factor 0x3611-26
defines
the gearing ratio factor
Speed
0x3611-15
defines the differential speed for the slave phase shift adjustment
Accel
0x3611-19
defines the acceleration value for acceleration phase, deceleration
phase and slave phase shift adjustment
MasterDtn 0x3611-13
defines the master distance
SlaveDtn
0x3611-14
defines the slave distance
SyncDtn 0x3611-16
defines
the synchronization distance
EndCond 0x3611-11
0x3611-12
see sequence parameters