XtrapulsPac - User Guide
Chapter 3 – Reference
Dataflow
An element of an object is qualified as dataflow (signal) if it is a variable (i.e. mappable).
These variables can be of 8 bit, 16 bit or 32 bit.
Depending on the using context, a dataflow must be of 16 bit or 32 bit or any size.
The dataflow can be issued from:
-
An external source:
Examples : Encoder position 0x3129-0
Analog Input 0x31F1-1 (16 bit)
Analog Input 0x31F1-2 (32 bit)
-
The CAN bus:
Example: Interpolated data 0x30C1-0 (32 bit)
-
An internal signal:
Examples: Profile Speed Function Block output 0x3526-0 (32-bit)
User variable : 0x3710-3 (32-bit)
3.1 - CANOPEN COMMUNICATION
3.1.1
-
C
OMMUNICATION OBJECTS
3.1.1.1 - CAN Telegram
CAN TELEGRAM
SOM COB-ID RTR CTRL Data segment
CRC ACK EOM
SOM
Start Of Message
COB-ID
COB-Identifier of 11 bits
RTR
Remote Transmission Request
CTRL Control
field
Data
up to 8 bytes
CRC
Cyclic Redundancy Check
ACK Acknowledge
EOM
End Of Message