137
XtrapulsPac - User Guide
Chapter 3 – Reference
3.2.3.7 - Profile Torque Mode
Profile Torque Mode
In this mode, the drive operates only with current loops and there is no speed or position control.
Object Dictionary Entries
Index Object
Name
Type
Attr.
0x6071 VAR
Target
Torque
Integer16
rw
0x3071
VAR
Target Torque Input Source
Unsigned32
rw
0x6087 VAR
Torque
Slope
Unsigned32
rw
0x6088 VAR
Torque
Profile
Type
Integer16
rw
0x60B2 VAR
Offset
Torque
Integer16
rw
0x6074
VAR
Torque Demand Value
Integer16
ro
0x6077
VAR
Torque Actual Value
Integer16
ro
0x6078
VAR
Current Actual Value
Integer16 ro
0x6079 VAR
DC
Voltage
Integer16
ro
Target Torque
is the input value for the current loop in profile torque mode. The value is given per thousand of the
rated current (0x6075).
Index 0x6071
Name Target
Torque
Object Code
VAR
Data Type
Integer16
Object Class
pt
Access rw
PDO Mapping
Possible
Unit
per thousand of rated current (0x6075)
Value Range
-
Default Value
0
Profile Torque Mode Input Source
Index 0x3071
Name
Profile Torque Mode Input Source for Target Torque
Description Index/sub-index of input data
Data Type
Unsigned32
Class pt
Access rw
PDO Mapping
No
Value See
below
Default Value
0x60710000
This object allows connecting any 16-bit dataflow as a target torque for the Profile Torque Mode.
The structure of the entries is the following:
MSB
LSB
Index (16-bit)
Sub-index (8-bit)
0
Example:
0x3071,0 = 0x30F10100
connects analog input 1 as the target torque for Profile Torque Mode.