166
XtrapulsPac – User Guide
Chapter 3 - Reference
Simple count:
Double count:
Sub Index
5
Description
Stepper input filter proportional gain
Data Type
Unsigned16
Access rw
PDO Mapping
No
Value 0-65535
Remark
This parameter value is automatically calculated when a cut off frequency value is
selected (see 0x3683).
Sub Index
6
Description
Stepper input filter integral gain
Data Type
Unsigned16
Access rw
PDO Mapping
No
Value
0-65535
Remark
This parameter value is automatically calculated when a cut off frequency value is
selected (see 0x3683).
Low-pass filter acting on the “Stepper input” position.
Index 0x3683
Name
Stepper input filter cut off frequency
Object Code
VAR
Data Type
Integer16
Object Class
se
Access rw
PDO Mapping
No
Unit Hz
Possible values
200, 100, 40, 20
Default Value
40
Remark
Stepper input filter proportional gain (0x3681,5) and integral gain (0x3681,6) are
automatically calculated according to the cut-off frequency selection.
PULSE input
PULSE_CNT
output
10 ms
10 ms
PULSE input
PULSE_CNT
output