56
XtrapulsPac – User Guide
Chapter 3 - Reference
Device Config
Index 0x3442
Name Device
Config
Object Code
VAR
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Default Value
0
Saved in DRIVEPAR.TXT
The device config allows activating drive specific functions.
Bit Number Function
0..5 Reserved
6
Activate motor zero speed detection.
Parameters for motor zero speed detection are velocity threshold (0x606F,0) and
velocity threshold time (0x6070,0).
When zero speed is detected, bit 6 of Device status is set.
7..15 Reserved
In position signal configuration
Index
0x306B
Description
In position signal delay
Object Code
VAR
Data Type
Unsigned16
Object Class
pp ip hm eg
Access rw
Unit ms
PDO Mapping
No
Default Value
0
Index
0x306E
Description
In position signal threshold
Object Code
VAR
Data Type
Unsigned16
Object Class
pp ip hm eg
Access rw
Unit
User position unit /s
PDO Mapping
No
Default Value
0
When the position set point changing is lower than the threshold value, and the delay value is over, bit 8 of the
device status (0x3441,0) is set.