211
XtrapulsPac - User Guide
Chapter 3 – Reference
Touch Probe Source
Index 0x60D0
Name
Touch Probe Source
Object Code
ARRAY
Number of Elements
2
Value Description
Value Touch
Probe
Source
-15 Resolver
TopZ
-14 Encoder
TopZ
-13
Analog In 2
-12
Analog In 1
-5 IN5
1 IN1
2 IN2
3 IN3
4 IN4
6 TopZ
Sub Index
1
Description
Touch Probe 1 Source
Data Type
Integer16
Access rw
PDO Mapping
No
Value
See table above
Default Value
3
Sub Index
2
Description
Touch Probe 2 Source
Data Type
Integer16
Access rw
PDO Mapping
No
Value
See table above
Default Value
-5
3.2.5.6 - Modulo function
Index 0x307B
Name Modulo
configuration
Object Code
VAR
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Default Value
0
The motor position can be limited by the position limit function (modulo function).
Minimum Position Limit <= Motor Position < Maximum Position Limit