XtrapulsPac – User Guide
Chapter 3 - Reference
Error
Code
Protection
Possible Stop on error
selection
Remarks
34
Velocity following error
Stop 0 or Stop 2 or Stop 3
Stop 2 selection requires a careful
fault occurrence analysis
35
Position following error
Stop 0 or Stop 2 or Stop 3
Stop 2 selection requires a careful
fault occurrence analysis
36
Software position limit
Stop 0 or Stop 2 or Stop 3
Stop 2 selection requires a careful
fault occurrence analysis
37
Motor Temperature error
Stop 0 or Stop 2 or Stop 3
Stop 2 selection requires a careful
fault occurrence analysis
38
I²t error
Stop 0 or Stop 2 or Stop 3
Stop 2 selection requires a careful
fault occurrence analysis
46
Extension Error or
Fieldbus watchdog error
Stop 0 or Stop 2 or Stop 3
Stop 2 selection requires a careful
fault occurrence analysis
49
Fieldbus SYNC cycle error
Stop 0 or Stop 2 or Stop 3
Stop 2 selection requires a careful
fault occurrence analysis
50
Fieldbus IP reference
underflow/overflow
Stop 0 or Stop 2 or Stop 3
Stop 2 selection requires a careful
fault occurrence analysis
51
Fieldbus guarding error
Stop 0 or Stop 2 or Stop 3
Stop 2 selection requires a careful
fault occurrence analysis
58
CAN Extension Module
communication lost or not found
Stop 0 or Stop 2 or Stop 3
Stop 2 selection requires a careful
fault occurrence analysis
Other
Stop 0 only
Important note
: When a Stop 2 or Stop 3 is executed due to a fault occurrence, a second fault occurrence with
Stop 2 or Stop 3 selection cannot be considered.
Sub Index
7
Description
AOK mask 1
Data Type
Unsigned32
Object Class
all
Access rw
PDO Mapping
No
Value See
0x3022-1
Default value
0x0000 0004 (UnderVoltage)
Sub Index
8
Description
AOK mask 2
Data Type
Unsigned32
Object Class
all
Access rw
PDO Mapping
No
Value See
0x3022-2
Default value
0x0000 0000
These 2 elements (0x3025,7 and 0x3025,8) allow selecting the errors not considered for the AOK signal
deactivation. Errors with the higher criticism regarding fire risk (power stage, braking system) cannot be masked.