230
XtrapulsPac – User Guide
Chapter 3 - Reference
Factor Group
0x608F
PosResol
Encoder Position Resolution
0x6093
Pos1Fact
Position Factor
0x6089 0
Pos1Nota
0x608A 0
Pos1Dim
0x3089 0
Pos1Disp
Position Display Factor
0x308A 0
Pos1Unit
Position Unit Name
Motor
0x6410
Motor Data
1
MotorMan
2
MotorNm
3
MotorCod
4
McatDate
5
MmodDate
6
Mtype
7
Mmaxspd
8
Mrtdspd
9
MstallI
10
MpeakI
11
M_Kt
12
M_J
13
Minduct
14
Mpolepr
15
MPhase
16
Moffset
17
MTtype
18
MTthres1
19
MTthres2
20
Mpolept
0x6072
MaxTq
Max Torque
0x6073
MaxI
Motor Max current
0x6075
MotRtdI
Motor Rated Current
0x6076
MotRtdTq
Motor Rated Torque
0x3410
MotorPar
Motor Parameters
1
PolePair
Current Number of motor pole pairs
2
MotPhase
Current Motor Phase
3
RotorOfs
Current Motor Offset
0x340F
0
Induct
Current Motor Inductance
0x3323
0
MT_res
Motor temperature probe monitoring
0x3324
MT_cfg
Motor temperature probe config
1
MT_probe
Motor temperature type (NTC/PTC)
2
MT_warn
Motor temperature warning threshold
3
MT_error
Motor temperature error threshold