224
XtrapulsPac – User Guide
Chapter 3 - Reference
CANopen I/O values
Index 0x3829
Name
CANopen I/O values
Object Code
RECORD
Number of Elements
4
Value Description
Sub Index
1
Description Digital
Inputs
this variable is read from CANopen I/O module digital inputs by SDO/PDO
Data Type
Unsigned16
Access rw
PDO Mapping
Yes
Sub Index
2
Description Digital
Outputs
this variable is sent to CANopen I/O module digital outputs by SDO/PDO
Data Type
Unsigned16
Access rw
PDO Mapping
Yes
Sub Index
3
Description Analog
Input
this variable is read from CANopen I/O module analog input by SDO/PDO
Data Type
Integer16
Access rw
PDO Mapping
Yes
Sub Index
4
Description Analog
Outputs
this variable is sent to CANopen I/O module analog outputs by SDO/PDO
Data Type
Integer16
Access rw
PDO Mapping
Yes
3.2.6
-
M
AINTENANCE
3.2.6.1 - Files
XtrapulsPac Files
The
XtrapulsPac
drive can store data files in its internal Flash memory:
Name Format
Description
DRIVEPAR.TXT text
object file
Drive parameters are saved in these files.
The user can save drive parameters by means of the Gem Drive
Studio software or via the communication bus by means of object
0x1010 (CAN bus, RS-232...)
USER_PAR.TXT text
object file
This file can keep extra parameters by the user.
The parameters are set manually and the USER_PAR.TXT file
must be sent to the
XtrapulsPac
drive.
SEQUENCE.TXT text
sequence file
Sequence files for Positioner Mode