169
XtrapulsPac - User Guide
Chapter 3 – Reference
3.2.3.12 - Gearing Mode
The gearbox mode is an operation mode which supports gearbox function. The main gearbox control takes effect
with the operation mode specific bits in control word (0x6040) and main gearbox indicators are in operation mode
specific bits of status word (0x6041).
Mode of Operation: -6
Control Word (0x6040):
Bit Action
4 1
Gearbox
Enable
0 Gearbox
disable
5
Start Slave Phase Shift Adjustment
12
Start Master Phase Shift Adjustment
Status Word (0x6041):
Bit Action
10 InGear
12 Gearbox
running
13
Gearbox mode parameters:
config:
0x3928,1
Defines the gearing behaviour:
- Exit Mode
- Trigger Mode
- Start Mode
- Ratio Set Select
- Ratio Modulation Enable
factor:
0x3928,2
Defines the gearing ratio factor value
acceleration:
0x392A,0
Defines the acceleration value of the slave for the acceleration phase, deceleration
phase and adjustment phase.
speed:
0x392C,0
Defines the relative speed for the slave phase shift adjustment.
master distance:
0x3925,1
Defines the distance of the master from the start to the synchronization point.
slave distance:
0x3925,2
Defines the distance of the slave from the start to the synchronization point.
If the slave distance is 0, then the adjustment is not executed.
The master distance and the slave distance parameters must be adjusted so that the
slave is synchronized before the synchronization point.
synchronization
distance:
0x3925,3
Defines the distance of the slave so that the slave must be synchronized in position.
If the synchronization distance is 0, then the slave will indefinitely synchronize with the
master. A stop condition can be used to exit the gearing sequence.