175
XtrapulsPac - User Guide
Chapter 3 – Reference
Index 0x391D
Name
Master phase shift distance
Object Code
VAR
Data Type
Integer32
Object Class
all
Access ro
PDO Mapping
Yes
Unit
master position unit
Default Value
-
This object defines the master distance for the master phase shift movement.
Master-Slave Control
Index 0x3940
Name Master-Slave
Control
Object Code
VAR
Data Type
Unsigned16
Object Class
gb, cm, sq
Access rw
PDO Mapping
Possible
Default Value
0
This object allows controlling behaviours of master/slave function.
Bit Number Function
0,1 Reserved
2
Slave Phase Shift
3 Reserved
4 Jog+
5 Jog-
6 Reserved
7 Master
Phase
Shift
8 Selection
For gear function:
0
gearing ratio set 1
1
gearing ratio set 2
This bit has effect only if gearbox configuration bit 9 is set. Gearbox configuration is
defined by 0x3928,1 for gearing mode or directly defined in sequence parameters for
gearing sequence.
This bit allows selecting and changing the ratio set on-the-fly.
For cam function:
0
cam profile 0
1
cam profile 1
This bit has effect only if cam configuration bit 9 is set. Cam configuration is defined
by 0x3938,1 for cam mode or directly defined in sequence parameters for cam
sequence.
This bit allows selecting and changing the cam profile on-the-fly.
9
For gear function:
On rising edge, new gearing ratio values (defined in 0x3921) are applied.
This bit allows changing the gearing ratio value on-the-fly.
10..15 Reserved