Index 0x6080
Name
Max Motor Speed
Object Code
VAR
Data Type
Integer32
Object Class
all
Access rw
PDO Mapping
No
Unit rpm
Value Range
100...60000
Default Value
3000
The
Max. motor speed
defines the maximum speed the drive can reach. To avoid a saturation of the servo loop,
the running speed must be less than
Max. motor speed
(depends on the overshoot accepted for the servo loop
response).
This parameter modifies the value of the Max Profile Velocity 0x607F.
Index 0x6081
Name Profile
Velocity
Object Code
VAR
Data Type
Unsigned32
Object Class
pp
Access rw
PDO Mapping
Possible
Unit User
Velocity
Unit
Value Range
-
Default Value
0x1000
The
Profile Velocity
is the running velocity for a positioning. If the positioning is too short, the profile velocity may
not be reached.
Index 0x6082
Name End
Velocity
Object Code
VAR
Data Type
Unsigned32
Object Class
pp
Access rw
PDO Mapping
Possible
Unit User
Velocity
Unit
Value Range
-
Default Value
0
The
End Velocity
is the final velocity value when the target position is reached. When the motor has to stop at the
target position,
End Velocity=0
.
Index 0x6083
Name Profile
Acceleration
Object Code
VAR
Data Type
Unsigned32
Object Class
pp
Access rw
PDO Mapping
No
Unit
User acceleration unit
Value Range
-
Default Value
0x10000