86
XtrapulsPac – User Guide
Chapter 3 - Reference
Sub Index
5
Description
d-Loop Integral Gain
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Value Range
0.. 65535
Default Value
Torque Offset: This object allows adding an offset to the torque command.
Index 0x60B2
Name Torque
Offset
Object Code
VAR
Data Type
Integer16
Object Class
all
Access rw
PDO Mapping
Yes
Unit
per thousand of rated current (0x6075)
Default Value
0
Index 0x30B3
Name Torque
Offset
2
This object allows adding an offset to the current command.
Object Code
VAR
Data Type
Integer16
Object Class
all
Access rw
PDO Mapping
Yes
Unit
per thousand of rated current (0x6075)
Default Value
0
The "Current Actual Value" gives the value of the DC current in the drive. This signal is filtered by a low-pass filter
(0x3078)
Index 0x6078
Name
Current Actual Value
Object Code
VAR
Data Type
Integer16
Object Class
all
Access ro
PDO Mapping
Yes
Unit
per thousand of motor rated current (0x6075)
Value Range
-
Default Value
-
Low-pass filter on “Current Actual Value” (0x6078)
Index 0x3078
Name
Current measurement filter
Object Code
VAR
Data Type
Integer16
Object Class
all
Access rw
PDO Mapping
No
Unit Hz
Defaut Value
1000