120
XtrapulsPac – User Guide
Chapter 3 - Reference
Bit change_set_immediately = 0 :
Object Dictionary Entries
Index Object
Name
Type
Attr.
0x607A VAR
Target
Position
Integer32
rw
0x6080
VAR
Max Motor Speed
Unsigned16
rw
0x6081 VAR
Profile
Velocity
Unsigned32
rw
0x6082 VAR
End
Velocity
Unsigned32
rw
0x6083 VAR
Profile
Acceleration
Unsigned32
rw
0x6084 VAR
Profile
Deceleration
Unsigned32
rw
0x6086 VAR
Motion
Profile
Type
Integer16
rw
0x6067 VAR
Position
Window
Unsigned32
rw
0x6068
VAR
Position Window Time
Unsigned16
rw
0x607F
VAR
Max Profile Velocity
Unsigned32
rw
0x3081
VAR
Speed Modulation Source
Unsigned32
rw
Index 0x607A
Name Target
Position
Object Code
VAR
Data Type
Integer32
Object Class
pp
Access rw
PDO Mapping
Yes
Unit User
Position
Unit
Value Range
(-2
31
)..(2
31
-1)
Default Value
0
Target position
is the final position where the motor will move to in profile position mode. The start position is the
current position. The positioning begins with rising edge of bit 4 of the control word (new set point). Bit 6 of control
word indicates if the target position is absolute (=0) or relative (=1) movement.
new set point
set point acknowledgement