74
XtrapulsPac – User Guide
Chapter 3 - Reference
Stop Current Limit
Index 0x3301
Name
Stop Current Limit
Object Code
ARRAY
Number of Elements
2
Value Description
Sub Index
1
Description
Stop Current Limit 1
This parameter defines the current limit when a stop on current limit is performed.
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Unit
per thousand of rated current
Value Range
100..6000
Default Value
1000
This parameter is used with a Quick Stop with Quick Stop Option Code = 3 or 7 (Stopped on current).
This parameter is also applied with a stop at limit switches.
Sub Index
2
Description
Stop Current Limit 2
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Unit
per thousand of rated current
Value Range
100..6000
Default Value
1000
This parameter is reserved for future use.
Stop Time Limit
Index 0x3302
Name
Stop Time Limit
Object Code
ARRAY
Number of Elements
2
These parameters define the time limit for a stop operation.
When a stop on current limit is executed, the end of the stop may not be correctly detected if the axis is
oscillating. The time stop limit allows limiting the execution time of the stop operation.
Value Description
Sub Index
1
Description
Stop Time Limit 1
Time limit for all stop operations with ramp.
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Unit ms
Value Range
0..65000
Default Value
1000