179
XtrapulsPac - User Guide
Chapter 3 – Reference
The structure of the entries is the following:
MSB
LSB
Index (16-bit)
Sub-index (8-bit)
0
Example:
0x3901,0 = 0x30F10200
connects analog input 1 (32-bit format) to the virtual master speed input (0x3902,0).
Index 0x3902
Name Virtual
Master
Speed
defines the target for the virtual master.
Object Code
VAR
Data Type
Integer32
Object Class
all
Access rw
PDO Mapping
No
Unit User
Velocity
Unit
Default Value
0
Index 0x3903
Name Virtual
Master
Acceleration
defines the acceleration for virtual master
Object Code
VAR
Data Type
Unsigned32
Object Class
-
Access rw
PDO Mapping
No
Unit
User acceleration unit
Default Value
-
Index 0x3906
Name Virtual
Master
Output
Object Code
VAR
Data Type
Integer32
Object Class
-
Access ro
PDO Mapping
Yes
Unit position
unit
Default Value
-
This object gives the output value of the virtual master. This value:
- can be applied directly to master-slave functions or
- sent to other drives via the CAN bus. In this case, the virtual master output must also be sent to this drive