73
XtrapulsPac - User Guide
Chapter 3 – Reference
Slow Down Ramp
Index 0x3300
Name
Slow Down Ramp
Object Code
ARRAY
Number of Elements
2
These parameters define the slow down deceleration with a stop executed with stop option code = 1 or 5
(Stopped on Slow down ramp).
Value Description
Sub Index
1
Description
Slow Down Ramp 1
Data Type
Unsigned32
Object Class
all
Access rw
PDO Mapping
No
Unit Acceleration
unit
Default Value
Sub Index
2
Description
Slow Down Ramp 2
reserved for future use.
Data Type
Unsigned32
Object Class
all
Access rw
PDO Mapping
No
Unit Acceleration
unit
Default Value
Quick Stop Ramp
Index 0x6085
Name
Quick Stop Ramp
Object Code
VAR
Data Type
Unsigned32
Object Class
all
Access rw
PDO Mapping
No
Unit Acceleration
unit
Default Value
0x00200000
This object defines the deceleration for a quick stop with Quick Stop Option Code = 2 or 6 (Stopped on Quick
Stop ramp).