184
XtrapulsPac – User Guide
Chapter 3 - Reference
Gearbox Ratio Parameters
Index 0x3921
Name Gearbox
Ratio
Parameters
Object Code
ARRAY
Number of Elements
4
Value Description
Sub Index
1
Description
Gearbox ratio set 1 numerator
Data Type
Unsigned32
Access rw
PDO Mapping
No
Range
1 to 65536
Sub Index
2
Description
Gearbox ratio set 1 denominator
Data Type
Unsigned32
Access rw
PDO Mapping
No
Range
1 to 65536
Gearing ratio 1 value = Numerator1 / Denominator1, Gearing ratio range is from 1/256 to 256.
Sub Index
3
Description
Gearbox ratio set 2 numerator
Data Type
Unsigned32
Access rw
PDO Mapping
No
Range
1 to 65536
Sub Index
4
Description
Gearbox ratio set 2 denominator
Data Type
Unsigned32
Access rw
PDO Mapping
No
Range
1 to 65536
Gearing ratio 2 value = Numerator2 / Denominator2, Gearing ratio range is from 1/256 to 256.
Gearbox Distances Parameter
This object defines Master Distance, Slave Distance and Synchronization Distance for the gearbox mode.
For gearbox sequence in sequence mode, there are 3 equivalence parameters defined in each sequence.
Index 0x3925
Name
Gearbox Distances Parameter
Object Code
ARRAY
Object Class
sq, gb
Number of Elements
3
Value Description
Sub Index
1
Description Master
Distance
Data Type
Integer32
Access rw
PDO Mapping
No
Unit Position
Unit