135
XtrapulsPac - User Guide
Chapter 3 – Reference
Index 0x6083
Name Profile
Acceleration
Object Code
VAR
Data Type
Unsigned32
Object Class
pp
Access rw
PDO Mapping
No
Unit
User acceleration unit
Value Range
-
Default Value
0x10000
Index 0x6084
Name Profile
Deceleration
Object Code
VAR
Data Type
Unsigned32
Object Class
pp
Access rw
PDO Mapping
No
Unit
User acceleration unit
Value Range
-
Default Value
0x10000
The
Velocity Window
defines a symmetrical range of accepted velocity relatively to the target velocity. If the
motor current velocity is within the velocity window, this target velocity is considered as reached (bit 10 of status
word - Target Reached – is set). If the velocity window value is 0, the velocity window control is not active.
Index 0x606D
Name Velocity
Window
Object Code
VAR
Data Type
Unsigned32
Object Class
pv
Access rw
PDO Mapping
No
Unit Velocity
Unit
Default Value
0
When the actual velocity is within the
Velocity Window
during the defined
Velocity Window Time
, the
corresponding bit 10 Target reached in the StatusWord will be set at 1.
Index 0x606E
Name
Velocity Window Time
Object Code
VAR
Data Type
Unsigned16
Object Class
pv
Access rw
PDO Mapping
Possible
Unit ms
Value Range
0...32767
Default Value
0