72
XtrapulsPac – User Guide
Chapter 3 - Reference
Disable Operation Option Code
Index 0x605C
Name
Disable Operation Option Code
Object Code
VAR
Data Type
integer16
Object Class
all
Access rw
PDO Mapping
No
Default Value
1
This object defines the stop behaviour when a DISABLE_OPERATION command is executed (see Drive State
Machine transition 5).
Disable operation
option code
Action
0 Disable
operation
1
Stopped on Slow down speed ramp
2
Stopped on Quick Stop speed ramp
3
Stopped on current limit
Inhibit Option Code
Index 0x305A
Name Inhibit
Option
Code
Object Code
VAR
Data Type
integer16
Object Class
all
Access rw
PDO Mapping
No
Default Value
1
This object defines the stop behaviour when an Inhibit logic input is activated (see Digital Inputs 0x60FD).
Inhibit option code
Action
0 Disable
drive
1
Stopped on Slow down speed ramp and disabled
2
Stopped on Quick Stop speed ramp and disabled
3
Stopped on current limit and disabled