109
XtrapulsPac - User Guide
Chapter 3 – Reference
Index 0x606C
Name
Velocity Actual Value
Object Code
VAR
Data Type
Integer32
Object Class
all
Access ro
PDO Mapping
Yes
Unit User
Velocity
Unit
The "Velocity Actual Value" gives the value of the actual motor velocity in user unit. This signal is filtered by a low-
pass filter defined by 0x306C.
Object 0x3069 gives the same Actual Velocity but in rpm unit.
Object 0x30F8-2 gives the actual velocity without the low-pass filter.
Index 0x306C
Name
Actual Velocity Filter
Object Code
VAR
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Unit 0.1Hz
Value Range
Default Value
800 (80Hz)
The filter is applied on “Velocity Actual Value” (0x606C,0)
Actual Velocity without this filtering: “Velocity Feedback” (0x30F8,2)
Index 0x306D
Name
Speed Following Error
Object Code
VAR
Data Type
Unsigned32
Object Class
pv pp ip hm
sq sm se gb cm
Access rw
PDO Mapping
Yes
Unit inc/s
Value Range
0..0xFFFFFFFF
Default Value
0xFFFFFFFF
This object defines the tolerance for the speed error value:
| Speed Demand – Actual Speed | < Speed Following Error
If the value of the parameter is FFFF FFFFh, the speed following error control is not operating.